Type spectrum
05.05
2-8
Siemens AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
The retrofit kit must be ordered to install boards in the SMOREG converter so that the correct connectors
for system cabling and the Short Guide are also available.
The LBA local bus adapter and ADB adapter board must be ordered as additional components for
installing supplementary boards in the SIMOREG converter. These adapters are available under
separate order numbers.
2) A pulse encoder evaluation circuit is a standard component of the basic SIMOREG converter. The SBP
need therefore be ordered only in configurations requiring evaluation of a second pulse encoder.
3) An LBA local bus adapter is required to install this board in a SIMOREG converter. The adapter is
available under a separate order number.
4) Supplied packed separately, including 10 m fiber-optic cable.
5) The last figure in the order code identifies the module location or slot of the electronic box (see Section
5.3.2):
1 . . . Board location 2
2 . . . Board location 3
4 . . . Slot D
5 . . . Slot E
6 . . . Slot F
7 . . . Slot G
2.5
Reference to new products
Converter Commutation Protector
The SIMOREG CCP Converter Commutation Protector can be supplied as an option for the
converters in the SIMOREG 6RA70 series.
Field of application:
The SIMOREG CCP converter commutation protector is for protecting semiconductor fuses of a
line-commutated power converter in inverter mode. If the inverter stalls, a large current is created
in the regenerating direction via the power system or a crossover current is created in the power
converter. The SIMOREG CCP limits this current to a harmless level so that thyristors and the
associated super-fast fuses are protected. As a result, time-consuming and expensive replacement
of the fuses after an inverter stalls is no longer necessary. Stalling of the inverter cannot be
prevented but its effects can. Another consequence is that a converter can be operated without
fuses.
Compatibility:
The SIMOREG CCP is only compatible with line-commutated converters of the 6RA70 series (and
newer ones) because sensor activity and fault evaluation can only take place here.
Use with converters connected in parallel is possible.
The SIMOREG CCP Converter Commutation Protector is operated via the SIMOREG unit
(parameterization, fault messages). Version 2.2 or a later software version must be installed in the
SIMOREG unit.
For more information and help selecting the most suitable unit for your application, please contact
your local SIEMENS Sales Office.
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......