05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-7
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
o13
Software update in progress
o13.0 Waiting for arrival of start command from HEXLOAD PC routine
(press the DOWN key to abort this status and start a RESET)
o13.1 Deletion of Flash EPROM in progress
xxxxx Display of address currently being programmed
o13.2 The Flash EPROM has been successfully programmed
(a RESET is performed automatically after approx. 1 second)
o13.3 Programming of the Flash EPROM has failed
(press UP key to return to operating state o13.0)
o14
Loading of boot sector in progress
(this operation is performed only in factory)
o15
Electronics not connected to voltage
Dark display: Waiting for voltage at terminals 5U1, 5W1
(electronics supply voltage).
11.2
General visualization parameters
r001
(G113)
Display of terminals 4 and 5 (main setpoint)
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r002
(G113)
Analog input, terminals 103 and 104 (main actual value)
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r003
(G113)
Analog input, terminals 6 and 7 (selectable input 1)
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r004
(G114)
Analog input, terminals 8 and 9 (selectable input 2)
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r005
(G114)
Analog input, terminals 10 and 11 (selectable input 3)
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r006
(G115)
Analog output, terminals 14 and 15
Display of output value before normalization and offset
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r007
(G115)
Analog output, terminals 16 and 17
Display of output value before normalization and offset
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r008
(G116)
Analog output, terminals 18 and 19
Display of output value before normalization and offset
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
r009
(G116)
Analog output, terminals 20 and 21
Display of output value before normalization and offset
-200.0 to 199.99
[%]
0.01%
Ind: None
Type: I2
P052 = 3
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......