05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-115
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Limit-value monitors without filtering
U197
(2197)
*
S00
(B137)
Source for input signal (A) and operating point (B) for
FB 73
1
st
limit-value monitor without filtering
i001: Input
signal
i002: Operating
point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9186
Type: L2
P052 = 3
P051 = 40
Offline
U198
(2198)
S00
(B137)
Settable operating point for limit-value monitor
FB 73
Applied to connector K9186
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U199
(2199)
S00
(B137)
Hysteresis for 1
st
limit-value monitor without filtering
FB 73
0.00 to 100.00
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U200
(2200)
*
S00
(B137)
Source for input signal (A) and operating point (B) for
FB 74
2
nd
limit-value monitor without filtering
i001: Input
signal
i002: Operating
point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9187
Type: L2
P052 = 3
P051 = 40
Offline
U201
(2201)
S00
(B137)
Settable operating point for limit-value monitor
FB 74
Applied to connector K9187
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U202
(2202)
S00
(B137)
Hysteresis for 2
nd
limit-value monitor without filtering
FB 74
0.00 to 100.00
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U203
(2203)
*
S00
(B137)
Source for input signal (A) and operating point (B) for
FB 75
3
rd
limit-value monitor without filtering
i001: Input
signal
i002: Operating
point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9188
Type: L2
P052 = 3
P051 = 40
Offline
U204
(2204)
S00
(B137)
Settable operating point for limit-value monitor
FB 75
Applied to connector K9188
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
U205
(2205)
S00
(B137)
Hysteresis for 3
rd
limit-value monitor without filtering
FB 75
0.00 to 100.00
[%]
0.01%
Ind: None
FS=0.00
Type: O2
P052 = 3
P051 = 40
Offline
U206
(2206)
*
S00
(B137)
Source for input signal (A) and operating point (B) for
FB 76
4
th
limit-value monitor without filtering
i001: Input
signal
i002: Operating
point
Settings:
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: 2
FS=
i001: 0
i002: 9189
Type: L2
P052 = 3
P051 = 40
Offline
U207
(2207)
S00
(B137)
Settable operating point for limit-value monitor
FB 76
Applied to connector K9189
-200.00 to 199.99
[%]
0.01%
Ind: None
FS=0.00
Type: I2
P052 = 3
P051 = 40
Offline
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......