05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-143
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Technology controller: Control bits
U500
(2500)
*
S00
(B170)
Source for technology controller enabling command
FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U502
(2502)
*
S00
FDS
(B170)
PI/PID controller switchover
FB 114
0
PI controller (D component is applied only in actual-value
channel)
1
PID controller (D component is applied for control deviation)
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
U503
(2503)
*
S00
FDS
(B170)
Set P component to zero
FB 114
0
Set controller P component to zero (i.e. to obtain pure I
controller)
1
Controller P component is active
0 to 1
1
Ind: 4
FS=1
Type: O2
P052 = 3
P051 = 40
Offline
U504
(2504)
*
S00
FDS
(B170)
Set I component to zero
FB 114
0
Set controller I component to zero (i.e. to obtain pure P
controller)
1
Controller I component is active
0 to 1
1
Ind: 4
FS=1
Type: O2
P052 = 3
P051 = 40
Offline
Technology controller: Set I component
When the state of the binector selected in U506 switches from log. "0" to "1", the I component of the technology controller is set to the
value parameterized in U505.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and setting of the I
component.
U505
(2505)
*
S00
(B170)
Source for setting value for I component
FB 114
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U506
(2506)
*
S00
(B170)
Source for control bit "Set I component"
FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Technology controller: Output, limitation
U507
(2507)
*
S00
(B170)
Source for variable positive limit
FB 114
After multiplication with U508, the contents of the selected connector act as
a positive limit for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
Note:
If the selected connector contains a negative value, a negative maximum
value is applied to the output of this limiter stage.
All connector
numbers
1
Ind: None
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U508
(2508)
S00
FDS
(B170)
Positive limit for output of technology controller
FB 114
See also U507
0.0 to 199.9
[%]
0.1
Ind: 4
FS=100.0
Type: O2
P052 = 3
P051 = 40
Online
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......