Parameter list
05.05
11-48
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
P409
FDS
(G120)
K409 fixed value
is applied to connector K0409
-199.99 to 199.99
[%]
0.01%
Ind: 4
FS=0.00
Type: I2
P052 = 3
P051 = 40
Online
P410
FDS
(G120)
K410 fixed value
is applied to connector K0410
-199.99 to 199.99
[%]
0.01%
Ind: 4
FS=0.00
Type: I2
P052 = 3
P051 = 40
Online
P411
FDS
(G120)
K411 fixed value
is applied to connector K0411
-199.99 to 199.99
[%]
0.01%
Ind: 4
FS=0.00
Type: I2
P052 = 3
P051 = 40
Online
P412
FDS
(G120)
K412 fixed value
is applied to connector K0412
-32768 to 32767
1
Ind: 4
FS=0
Type: I2
P052 = 3
P051 = 40
Online
P413
FDS
(G120)
K413 fixed value
is applied to connector K0413
-32768 to 32767
1
Ind: 4
FS=0
Type: I2
P052 = 3
P051 = 40
Online
P414
FDS
(G120)
K414 fixed value
is applied to connector K0414
-32768 to 32767
1
Ind: 4
FS=0
Type: I2
P052 = 3
P051 = 40
Online
P415
FDS
(G120)
K415 fixed value
is applied to connector K0415
-32768 to 32767
1
Ind: 4
FS=0
Type: I2
P052 = 3
P051 = 40
Online
P416
FDS
(G120)
K416 fixed value
is applied to connector K0416
-32768 to 32767
1
Ind: 4
FS=0
Type: I2
P052 = 3
P051 = 40
Online
11.21 Fixed control bits
Function: The value set in the parameter is applied to the specified binector
P421
FDS
(G120)
B421 fixed bit
is applied to binector B0421
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P422
FDS
(G120)
B422 fixed bit
is applied to binector B0422
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P423
FDS
(G120)
B423 fixed bit
is applied to binector B0423
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P424
FDS
(G120)
B424 fixed bit
is applied to binector B0424
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P425
FDS
(G120)
B425 fixed bit
is applied to binector B0425
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P426
FDS
(G120)
B426 fixed bit
is applied to binector B0426
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P427
FDS
(G120)
B427 fixed bit
is applied to binector B0427
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
P428
FDS
(G120)
B428 fixed bit
is applied to binector B0428
0 to 1
1
Ind: 4
FS=0
Type: O2
P052 = 3
P051 = 40
Online
11.22 Digital setpoint input (fixed setpoint, inching and crawling setpoints)
(see also Section 8, Sheets G127, G129 and G130)
Fixed setpoint
Function: Up to 8 connectors can be selected in P431 indices .01 to .08. These can be applied as an additional fixed setpoint (K0204,
K0209) via the binectors selected in P430, indices .01 to .08 (setpoint is applied when binector switches to log. "1" state). P432
indices .01 to .08 can be set to define for each setpoint individually whether the ramp-function generator must be bypassed on
setpoint injection.
If fixed setpoint injection is not selected, the connector set in P433 is applied to K0209.
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......