Parameter list
05.05
11-180
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U961
(2961)
*
S00
Processing sequence of function blocks of S00 technology
software (2)
i001: Number of function block for 101
st
place in processing sequence
i002: Number of function block for 102
nd
place in processing
sequence
etc.
Numbers of all
function blocks
Ind: 100
FS=
Standard
sequence
Type: O2
P052 = 3
P051 = 40
Offline
U962
(2962)
*
S00
Processing sequence of function blocks of S00 technology
software (3)
i001: Number of function block for 201
st
place in processing sequence
i002: Number of function block for 202
nd
place in processing
sequence
etc.
Numbers of all
function blocks
Ind: 100
FS=
Standard
sequence
Type: O2
P052 = 3
P051 = 40
Offline
U969
(2969)
*
S00
Automatic setting and activation of the execution sequence
0 Return
1
Set standard sequence:
The numbers of the function blocks are entered in ascending
order in Parameters U960, U961 and U962. The parameter is
then automatically set to value 0.
2
Set optimum sequence:
U960, U961, and U962 are set in such a way that as few
deadtimes as possible occur. After that, the parameter is
automatically set to value 0 again.
3
Set standard setting of the sampling times.
U950, U951, and U952 are set to the factory setting.
4
Automatic activation / deactivation:
U950, U951 and U952 are set in such a way that the unwired
function blocks are deselected and the wired function blocks are
selected (activated), if they are not yet selected.
The time slice 10 (sampling time 20 ms) is set for all function
blocks not previously activated, the time slice is left unchanged
for all previously activated function blocks.
0 to 4
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
off-line
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......