05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-125
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Characteristic block 2
(output = K9230)
FB 107
Characteristic block 6
(output = K9412)
[SW1.8 and later]
FB
282
Characteristic block 7
(output = K9413)
[SW1.8 and later]
FB
283
U284
(2284)
*
S00
(B160)
Source for input quantity
0 = Connector K0000
1 = Connector K0001
etc.
up to SW 1.7:
Selected connector = input quantity for FB107
SW 1.8 and later:
i001
input quantity
for FB107
i002
input quantity
for FB282
i003
input quantity
for FB283
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U285
(2285)
S00
(B160)
x values
i001 1st
characteristic point
for FB107
i002
2nd characteristic point
for FB107
...
i010
10th characteristic point
for FB107
SW 1.8 and later:
i011 1st
characteristic point
for FB282
i012
2nd characteristic point
for FB282
...
i020
10th characteristic point
for FB282
i021 1st
characteristic point
for FB283
i022
2nd characteristic point
for FB283
...
i030
10th characteristic point
for FB283
-200.00 to 199.99
[%]
0.01
Ind: 30
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
U286
(2286)
S00
(B160)
y values
i001 1st
characteristic point
for FB107
i002
2nd characteristic point
for FB107
...
i010
10th characteristic point
for FB107
SW 1.8 and later:
i011 1st
characteristic point
for FB282
i012
2nd characteristic point
for FB282
...
i020
10th characteristic point
for FB282
i021 1st
characteristic point
for FB283
i022
2nd characteristic point
for FB283
...
i030
10th characteristic point
for FB283
-200.00 to 199.99
[%]
0.01
Ind: 30
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
Characteristic block 3
(Output = K9231)
FB 108
Characteristic block 8
(Output = K9414)
[SW1.8 and later]
FB
284
Characteristic block 9
(Output = K9415)
[SW1.8 and later]
FB
285
U287
(2287)
*
S00
(B160)
Source for input quantity
0 = Connector K0000
1 = Connector K0001
etc.
up to SW 1.7:
Selected connector = input quantity for FB108
SW 1.8 and later:
i001
Input quantity
for FB108
i002
Input quantity
for FB284
i003
Input quantity
for FB285
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......