Parameter list
05.05
11-14
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
r063
(G101)
Board code
Identification code of boards mounted in locations 1 to 3 of electronics box.
CUDx
F
D
E
G
1
3
2
Arrangement of
board locations 1 to 3
and slots D to G in
electronics box
i001: Board in location 1
71: CUD1
72: CUD1 + CUD2
i002: Board in slot D (upper slot of location 2)
111:
Pulse encoder board (SBP) [SW 1.8 and later]
131 to 139:
Technology board
141 to 149:
Communications board
151, 152, 161: Special board (EB1, EB2, SLB)
i003: Board in slot E (lower slot of location 2)
111:
Pulse encoder board (SBP) [SW 1.8 and later]
131 to 139:
Technology board
141 to 149:
Communications board
151, 152, 161: Special board (EB1, EB2, SLB)
i004: Board in slot F (upper slot of location 3)
111:
Pulse encoder board (SBP) [SW 1.8 and later]
141 to 149:
Communications board
151, 152, 161: Special board (EB1, EB2, SLB)
i005: Board in slot G (lower slot of location 3)
111:
Pulse encoder board (SBP) [SW 1.8 and later]
141 to 149:
Communications board
151, 152, 161: Special board (EB1, EB2, SLB)
Ind:
5
Type: O2
P052 = 3
r064
(G101)
Board compatibility
Compatibility identifier of boards in locations 1 to 3 of electronics box.
The compatibility identifier is bit-coded. To ensure the compatibility of a
board, it must have a "1" setting at the same bit location of the parameter
value as the CUD (in location 1 / index i001).
Indices:
i001: Compatibility identifier of board in location 1
i002: Compatibility identifier of board in slot D
i003: Compatibility identifier of board in slot E
i004: Compatibility identifier of board in slot F
i005: Compatibility identifier of board in slot G
Example:
Index Value
Bit representation
Compatible with CUD
i001
253
0000 0000 1111 1101
i002
002
0000 0000 0000 0010
no
i003
001
0000 0000 0000 0001
yes
Ind:
5
Type: O2
P052 = 3
r065
(G101)
Software identifiers
Extended software version identifiers in locations 1, 2, and 3 of the
electronics box
Indices:
i001: Software identifier of the board in location 1
i002: Software identifier of the board in slot D
i003: Software identifier of the board in slot E
i004: Software identifier of the board in slot F
i005: Software identifier of the board in slot G
Ind:
5
Type: O2
P052 = 3
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......