background image

SA-1000K & SA-3000K Series 

Pure Sine Wave Inverter 

User’s Manual

Summary of Contents for SA-1000K Series

Page 1: ...SA 1000K SA 3000K Series Pure Sine Wave Inverter User s Manual...

Page 2: ...2 2 2 Electrical Performance 3 4 2 3 Mechanical Drawings 5 6 3 Introduction 7 3 1 Front Panel operation 7 10 3 2 Rear Panel operation 11 12 3 3 Protections Features 12 3 4 Installation 13 3 5 Making...

Page 3: ...ion protected around the inverter 1 2 Precautions When Working with Batteries 1 2 1 If battery acid contacts skin or clothing you shall wash it out with soap and water immediately If battery acid cont...

Page 4: ...Input over voltage Over temperature 2 1 Application 2 1 1 Power tools circular saws drills grinders sanders buffers weed and hedge trimmers air compressors etc 2 1 2 Office equipment computers printer...

Page 5: ...5 VDC 21 0 30 VDC Input Level Indicator Red Orange Green LED Load Level Indicator Failure Indicator Red LED Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temper...

Page 6: ...ange Green LED Load Level Indicator Failure Indicator Red LED Protection Overload Short Circuit Reverse Polarity Fuse Over Under Input Voltage Over Temperature Remote Control Unit S R8 S R6 12 S R6 24...

Page 7: ...71 50 2 83 SK1000 88 00 3 46 SK1500 88 00 3 46 182 00 7 17 191 00 7 52 SA 1000K 154 00 6 06 S3 S2 PWR SAV I O S1 LOAD LEVEL INPUT LEVEL S4 STATUS FREQ 1000W Pure Sine Wave Power Inverter POS NEG DC IN...

Page 8: ...SA 3000K 398 00 15 67 Pure Sine Wave Power Inverter 165 25 6 51 209 00 8 23 AC OUTPUT PURE SINE WAVE INVERTER S4 FREQ S2 S1 S3 PWR SAV O I 0 REMO LOAD LEVEL STATUS INPUT LEVEL OFF ON I 177 00 6 97 20...

Page 9: ...Front Panel Operations 3 1 1 Front view 3 1 2 ON OFF REMOTE Main switch a Before installing the inverter you need to ensure the main switch must be OFF b Before using the remote unit you need to ensur...

Page 10: ...REEN 12 1 14 2 24 1 28 6 ORANGE Blink 14 2 15 0 28 6 30 0 OVER RED Blink 15 0 30 0 3 1 4 Load Level Display AC Loads Watts LED status DARK GREEN ORANGE RED RED BLINK SA 1000K 0 80W 80 330W 330 750W 75...

Page 11: ...Power Saving Mode is adjustable and set by the Dip Switches S1 S2 and S3 on the front panel Example With the watt setting at 15W a 15W load will make the inverter operate normally a 15W load will ente...

Page 12: ...3 1 8 AC outlets available Australia New Zealand IEC 2 Universal HARD WIRE United Kingdom IEC 1 North America GFCI NEMA 5 15R NEMA 5 20R Continental European 10...

Page 13: ...UNIT REMOTE PORT CHASSIS GROUND 3 2 1 Remote Port The SA Series Inverter is compatible with any of the remote controllers S R8 S R6 12 S R6 24 Before using the remote unit you need to ensure the main...

Page 14: ...21 0 30 0 3 2 4 Use wire 8 AWG to connect Chassis ground with vehicle chassis WARNING Operating the inverter without a proper ground Connection may cause an electrical hazard 3 3 Protections Features...

Page 15: ...m of the unit are not obstructed 3 4 5 Dust Do not install the Inverter in a dusty environments The dust can be inhaled into the unit when the cooling fan is working 3 4 6 Close to batteries Avoid exc...

Page 16: ...arrow or too long will deteriorate inverter performance such as poor surge capability and frequent low input voltage warnings and shutdowns These low input voltage warnings are due to DC voltage drop...

Page 17: ...orque to 9 10 ft lbs 11 7 13 Nm Loose connections may cause overheat and fire The installation of a fuse must be on a positive cable Failure to place a fuse on cables running between the inverter and...

Page 18: ...DO NOT OPEN NO USER SERVICEABLE PARTS INSIDE WARNING DC INPUT POS CHASSIS GROUND NEG REMOTE PORT Battery to inverter cable connection Do not place anything between battery cable lug and terminal surf...

Page 19: ...e Inverter is in bypass mode this connection the neutral of the Inverter s AC output to input safety ground is not present so that the utility neutral is only connected to ground at your breaker panel...

Page 20: ...the inverter will make self diagnosis and the LED s indicators will also appear various colors Finally the buzzer will Beep again and the Input Level and Status LED indicators will turn to Green color...

Page 21: ...red LED a Blinking fast Over input voltage OVP Check input voltage Reduce input voltage b Blinking slowly Low input voltage UVP Recharge battery Check connections and the cable c Blinking Intermitten...

Page 22: ...efects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us with postage paid P...

Page 23: ...0 17 Fawcett Road Coquitlam BC V3K 6V2 Canada Toll free phone 1 800 561 5885 Toll free fax 1 888 814 5210 General Inquiries samlex samlexamerica com WWW http www samlexamerica com 034_2009_SA 1000K_SA...