Parameter list
05.05
11-124
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Characteristic blocks
The curve of the characteristics can be defined by 10 points each:
Index i001 to i010 of the parameters for the x values (U282, U285, U288): x values for FB 106, FB 107, FB 108
Index i001 to i010 of the parameters for the y values (U283, U286, U289): associated y values
SW1.8 and later:
Index i011 to i020 of the parameters for the x values (U282, U285, U288): x values for FB 280, FB 282, FB 284
Index i011 to i020 of the parameters for the y values (U283, U286, U289): associated y values
Index i021 to i030 of the parameters for the x values (U282, U285, U288): x values for FB 281, FB 283, FB 285
Index i021 to i030 of the parameters for the y values (U283, U286, U289): associated y values
for x = -200.00% up to x value acc. to index i001 (or i011 or i021) of the parameter for the x values gilt:
y = value acc. to index i001 (or i011 or i021) of the parameter for the y values
for x = x value acc. to index i010 (or i020 or i030) of the parameter for the x values to x = 200.00% gilt:
y = value acc. to index i010 (or i020 or i030) of the parameter for the y values
The distance between two adjacent x or y values must not be more than 199.99% otherwise deviations from the required shape of the
characteristic can
Characteristic block 1
(output = K9229)
FB 106
Characteristic block 4
(output = K9410)
[SW1.8 and later]
FB
280
Characteristic block 5
(output = K9411)
[SW1.8 and later]
FB
281
U281
(2281)
*
S00
(B160)
Source for input quantity
0 = Connector K0000
1 = Connector K0001
etc.
Up to SW 1.7:
Selected connector = input quantity for FB106
SW 1.8 and later:
i001
Input quantity
for FB106
i002
Input quantity
for FB280
i003
Input quantity
for FB281
All connector
numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
off-line
U282
(2282)
S00
(B160)
x values
i001 1st
characteristic point
for FB106
i002
2nd characteristic point
for FB106
...
i010
10th characteristic point
for FB106
SW 1.8 and later:
i011 1st
characteristic point
for FB280
i012
2nd characteristic point
for FB280
...
i020
10th characteristic point
for FB280
i021 1st
characteristic point
for FB281
i022
2nd characteristic point
for FB281
...
i030
10th characteristic point
for FB281
-200.00 to 199.99
[%]
0.01
Ind:30
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
U283
(2283)
S00
(B160)
y values
i001 1st
characteristic point
for FB106
i002
2nd characteristic point
for FB106
...
i010
10th characteristic point
for FB106
SW 1.8 and later:
i011 1st
characteristic point
for FB280
i012
2nd characteristic point
for FB280
...
i020
10th characteristic point
for FB280
i021 1st
characteristic point
for FB281
i022
2nd characteristic point
for FB281
...
i030
10th characteristic point
for FB281
-200.00 to 199.99
[%]
0.01
Ind: 30
FS=0.00
Type: I2
P052 = 3
P051 = 40
on-line
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......