Function descriptions
05.05
9-28
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
connector at two contiguous indices of the selection parameter.
Examples:
.04
.01
.03
.02
P794
KK9498
KK9498
K0401
K0402
L-Word
H-Word
Word
Word
401
9498
9498
K
K
K
402
K
.04
.01
.03
.02
P794
KK9498
KK9499
K0401
K0402
H-Word
H-Word
Word
Word
401
9498
9499
K
K
K
402
K
2 different
double-word connectors
Diagnostics and monitoring functions for peer-to-peer link
All transmitted and received useful data words can be checked (directly at the internal software
transfer point from/to peer driver) by means of display parameters r812 / r813 or r814 / r815.
Diagnostic parameters r799 or r809 provide information about the chronological distribution of errored
and error-free telegrams, as well as the nature of any communication errors that have occurred. A
watchdog can be set in P797 or P807 which can initiate a shutdown on faults (F012 or F013) in the
case of timeout. By connecting binectors B6031 or B9031 to the fault message triggers (using
P798=6031 / P808=9031), it is possible to acknowledge these fault messages even if the fault is
active continuously, thereby ensuring that the drive can still be operated manually after the peer-to-
peer interface has failed.
Important !
The serial interfaces for the peer-to-peer protocol are parameterized with the same parameters used
to configure the USS protocol, although the setting ranges are different in some cases (see Notes for
relevant parameters in Parameter List, Section 11).
Peer-to-peer communication, 4-wire operation
Serial linking of converter to converter (partners of equal status).
The signal flow can pass through the drives, for example, in a series connection. In this case, each
drive forwards the data after processing only to the next drive (classic setpoint cascade).
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......