05.05
Parameter list
SIEMENS AG 6RX1700-0AD76
11-147
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Enable and setting of the PI controllers
U531
(2531)
*
S00
(B180...
B189)
Source for control signals (enable PI controller)
[SW 1.8 and later]
0 = Binector B0000
1 = Binector B0001
etc.
i001: 0 = Disable controller
PI controller 1
i002: 0 = Disable controller
PI controller 2
...
i010: 0 = Disable controller
PI controller 10
i011: 1 = Freeze I component
PI controller 1
i012: 1 = Freeze I component
PI controller 2
...
i020: 1 = Freeze I component
PI controller 10
i021: 1 = Freeze output
PI controller 1
i022: 1 = Freeze output
PI controller 2
...
i030: 1 = Freeze output
PI controller 10
i031: 1 = Freeze I component in pos.direction PI controller 1
i032: 1 = Freeze I component in pos.direction PI controller 2
...
i040: 1 = Freeze I component in pos.direction PI controller 10
i041: 1 = Freeze I component in neg.direction PI controller 1
i042: 1 = Freeze I component in neg.direction PI controller 2
...
i050: 1 = Stop I component in neg.direction
PI controller 10
All binector numbers
1
Ind: 50
WE=0
Typ: L2
P052 = 3
P051 = 40
off-line
U532
(2532)
*
S00
(B180...
B189)
Source for control signals (set PI controller)
[SW 1.8 and later]
0 = Binector B0000
1 = Binector B0001
etc.
i001: 0 = Set I component
PI controller 1
i002: 0 = Set I component
PI controller 2
...
i010: 0 = Set I component
PI controller 10
i011: 0 = Set output
PI controller 1
i012: 0 = Set output
PI controller 2
...
i020: 0 = Set output
PI controller 10
All binector numbers
1
Ind: 20
WE=0
Typ: L2
P052 = 3
P051 = 40
off-line
U533
(2533)
*
S00
(B180...
B189)
Source for Setting values
[SW 1.8 and later]
0 = Connector K0000
1 = Connector K0001
etc.
i001: Setting value for I component PI controller 1
i002: Setting value for I component PI controller 2
...
i010: Setting value for I component PI controller 10
i011: Setting value for Output PI controller 1
i012: Setting value for Output PI controller 2
...
i020: Setting value for Output PI controller 10
All connector
numbers
1
Ind: 20
WE=0
Typ: L2
P052 = 3
P051 = 40
off-line
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......