05.05
Start-Up
SIEMENS AG 6RX1700-0AD76
7-5
SIMOREG DC Master Operating Instructions
Control bits from OP1S operator panel:
(see also function diagram "OP1S operational display" (Section 8, Sheet Z123) and the OP1S
operating instructions)
Data are exchanged between the OP1S and SIMOREG 6RA70 converter via the G-SST1 interface
(RS485) and USS protocol.
The OP1S operator panel transfers the following control bits in process data word 1 in the USS
message:
Key on OP1S
Function *)
Bit in PZD word1
(connector K2001)
Binector
ON key / OFF key (I / 0) ON / OFF1
Bit 0
B2100
Reset Acknowledge
Bit
7
B2107
Jog
Jog (inch)
Bit 8
B2108
Reverse
Enable positive direction of rotation
Bit 11
B2111
Enable negative direction of rotation
Bit 12
B2112
UP key
Increase motorized potentiometer
Bit 13
B2113
DOWN key
Decrease motorized potentiometer
Bit 14
B2114
*) Suggested functions. Since binectors can be freely wired up to any selector switch, the control signals from the OP1S
can be used for any type of control task in the SIMOREG 6RA70.
Connection of control signals from the OP1S for the suggested functions:
Functions can be implemented via the OP1S only if the following conditions are fulfilled:
1) Bit-by-bit input of control bits in control word 1 (P648 = 9), see also Section 8, Function
Diagrams, Sheet G180
2) OP1S in "Operational display" status
ON / OFF1:
Parameterization of switch-on/shutdown via OP1S by setting
P654 = 2100
Please also note AND operation with "Switch-on/Shutdown" from terminal 37 (see also Function
Diagrams, Sheet G130 in Section 8 and Section "Switch-on/Shutdown (ON / OFF) terminal 37" in
Section 9)
Acknowledge:
Parameterization of fault message acknowledgements via OP1S by setting
P665, P666 or P667 = 2107
Faults can always be acknowledged by pressing the <P> key on the PMU.
Inching:
Parameterization of inching via OP1S by setting
P668 or P669 = 2108
Selection of source of inching setpoint via the corresponding index of P436 (see "Inching setpoint"
function diagram)
Direction of rotation enable:
Parameterization of direction of rotation enabling via OP1S by setting
P671 = 2111 (positive direction of rotation)
P672 = 2112 (negative direction of rotation)
Motorized potentiometer:
Parameterization of motorized potentiometer via OP1S by setting
P673 = 2113 (higher)
P674 = 2114 (lower)
P644 = 240 (main setpoint from motorized potentiometer)
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......