Start-Up
05.05
7-26
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
Index
Meaning for CBP2
001/033 CBP_Status
Bit0: "CBP Init", CBP is being initialized or waiting to be initialized by the basic unit
(not set in normal operation)
Bit1: "CBP Online", CBP is selected by basic unit
(set in normal operation)
Bit2: "CBP Offline", CBP not selected by basic unit
(not set in normal operation)
Bit3: Illegal bus address (P918)
(not set in normal operation)
Bit4: Diagnostic mode activated (U711 <> 0)
(not set in normal operation)
Bit8: Incorrect identifier bytes transferred (incorrect configuring message from PROFIBUS Master)
(not set in normal operation)
Bit9: Incorrect PPO type (incorrect configuring message from PROFIBUS Master)
(not set in normal operation)
Bit10: Correct configuring data received from PROFIBUS_DP Master (set in normal operation)
Bit12: Fatal error detected by DPS Manager software (not set in normal operation)
Bit13: Program in endless loop in main.c (loop can only be exited by a Reset)
Bit15: Program in communications online loop (loop can only be exited through re-initialization by basic unit)
002/034 SPC3_Status
Bit0: Offline/Passive Idle
(0=SPC3 is operating in normal mode (offline)
1=SPC3 is operating in Passive Idle)
Bit2: Diag flag
(0=diagnostic buffer has been picked up by master
1= diagnostic buffer has not been picked up by master)
Bit3: RAM Access Violation, memory access >1.5kB
(0=no address violation, 1=for addresses > 1536 bytes, 1024 is subtracted from address and access
made to the new address)
Bit4+5: DP state (00=Wait_Prm, 01=Wait_Cfg, 10=Data_Ex, 11=not possible)
Bit6+7: WD state (00=Baud search, 01=Baud_Control, 10=DP_Control, 11=not possible)
Bit8-11: Baud rate (0000=12MBd, 0001=6MBd, 0010=3MBd, 0011=1,5MBd, 0100=500kBd, 0101=187.5kBd,
0110=93.75kBd, 0111=45.45kBd, 1000=19.2kBd, 1001=9.6kBd)
Bit12-15: SPC3-Release (0000=Release 0)
003/035 SPC3_Global_Controls
Bits remain set until the next DP global command
Bit1: 1=Clear_Data message received
Bit2: 1=Unfreeze message received
Bit3: 1=Freeze message received
Bit4: 1=Unsync message received
Bit5: 1=Sync message received
004/036 L byte: No. of received error-free messages (DP Standard only)
H byte: Reserved
005/037 L byte: "Timeout" counter
H byte: Reserved
006/038 L byte: "Clear Data" counter
H byte: Reserved
007/039 L byte: "Heartbeat counter error" counter
H byte: Reserved
008/040 L byte: No. bytes for special diagnosis
H byte: Reserved
009/041 L byte: Mirroring of slot identifier 2
H byte: Mirroring of slot identifier 3
010/042 L byte: Mirroring of P918 (CB bus addr.)
H byte: Reserved
011/043 L byte: "Re-config. by CUD" counter
H byte: "Initialization runs" counter
012/044 L byte: Error ID DPS manager error
H byte: Reserved
013/045 L byte: PPO type found
H byte: Reserved
014/046 L byte: Mirroring of "DWord specifier ref"
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......