Parameter list
05.05
11-136
SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU
Description
Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U403
(2403)
*
S00
(B207)
Source for input signals, NAND element 4
(output = B9473)
FB
203
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U404
(2404)
*
S00
(B207)
Source for input signals, NAND element 5
(output = B9474)
FB
204
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U405
(2405)
*
S00
(B207)
Source for input signals, NAND element 6
(output = B9475)
FB
205
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U406
(2406)
*
S00
(B207)
Source for input signals, NAND element 7
(output = B9476)
FB
206
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U407
(2407)
*
S00
(B207)
Source for input signals, NAND element 8
(output = B9477)
FB
207
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U408
(2408)
*
S00
(B207)
Source for input signals, NAND element 9
(output = B9478)
FB
208
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U409
(2409)
*
S00
(B207)
Source for input signals, NAND element 10
(output = B9479)
FB
209
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U410
(2410)
*
S00
(B207)
Source for input signals, NAND element 11
(output = B9480)
FB
210
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U411
(2411)
*
S00
(B207)
Source for input signals, NAND element 12
(output = B9481)
FB
211
As for U400
All binector numbers
1
Ind: 3
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
11.69 Storage elements, timers and binary signal selector switches
Only active with optional technology software S00
RS flipflops
RS flipflops with SET (Q=1) and RESET (Q=0) (priority: 1
st
RESET, 2
nd
SET). RESET setting is enabled on POWER ON.
U415
(2415)
*
S00
(B210)
Source for SET and RESET for RS flipflop 1
FB 215
(Outputs: Q = B9550, /Q = B9551)
i001
Source for SET
i002
Source for RESET
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U416
(2416)
*
S00
(B210)
Source for SET and RESET for RS flipflop 2
FB 216
(outputs: Q = B9552, /Q = B9553)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U417
(2417)
*
S00
(B210)
Source for SET and RESET for RS flipflop 3
FB 217
(outputs: Q = B9554, /Q = B9555)
As for U415
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......