05.05
Description
Siemens AG 6RX1700-0AD76
3-3
SIMOREG DC Master Operating Instructions
3.4
Technical data
3.4.1 Load
types
To adapt the SIMOREG DC Master to the load profile of the working machine as efficiently as
possible, you can dimension it using the load cycle.
The setting on the SIMOREG DC Master is made in parameter P067.
Load class
Load for converter
Load cycle
DC I
(P067=1)
I
DC I
continuous (I
dN
)
100%
DC II
(P067=2)
I
DC II
for 15 min and 1.5 x I
DC II
for 60 s
100%
150%
15min
DC III
(P067=3)
I
DC III
for 15 min and 1.5 x I
DC III
for 120 s
100%
150%
15min
DC IV
(P067=4)
I
DC IV
for 15 min and 2 x I
DC IV
for 10 s
100%
200%
15min
US rating
(P067=5)
I
US
for 15 min and 1.5 x I
US
for 60 s
Note:
In this setting, an ambient or coolant
temperature of 45°C is permissible for all
device types.
100%
150%
15min
NOTICE
If you set a value of > 1 in P067, you must ensure that the "Dynamic overload capability of
power module“ is enabled, i.e. a value of > 0 must be set in parameter P075.
The SIMOREG DC Master does not monitor for compliance with the criteria of the load class
set in parameter P067. If permitted by the power module, the unit can operate for overload
periods in excess of those defined by the load class. The actual permissible overload period for
the installed power module is always longer than the overload period defined for the load class.
The SIMOREG DC Master does monitor the actual permissible overload period for the power
module. See Section 9.15.
Summary of Contents for 6RA7013-6DV62
Page 10: ...Contents 05 05 0 8 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 158: ...Connections 05 05 6 72 Siemens AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 648: ...Parameter list 05 05 11 184 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 720: ...Maintenance 05 05 13 10 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 728: ...Applications 01 04 17 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 730: ...Appendix 05 05 18 2 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 732: ...Appendix 05 05 18 4 SIEMENS AG 6RX1700 0AD76 SIMOREG DC Master Operating Instructions ...
Page 733: ......