Page 2: ...l represent the technical status at the time of writing and are subject to change without prior notice We have done our best to ensure that the information given in this manual is useful accurate and...

Page 3: ...ents 6 4 Recycling 7 5 Main features 8 6 Device overview 9 7 Link speeds 10 8 Conversion modes 11 8 1 PTP mode 11 8 2 Direct mode 11 8 2 1 Network TAP 11 8 2 2 Long distance fiber connections 12 9 Pow...

Page 4: ...es A media converter like EMCON 200 is used to connect your devices with a twisted pair Ethernet port to optical fiber networks Furthermore you can use EMCON 200 in networks with IEEE 1588 Precision T...

Page 5: ...astic bags that may pose a choking hazard to children EMCON 200 and its accessories shall only be used when in a technically sound condition Before use always check EMCON 200 and its accessories for d...

Page 6: ...talled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Page 7: ...trical and Electronic Equipment Directive WEEE directive As part of our legal obligations under this legislation OMICRON offers to take back the device and ensure that it is disposed of by authorized...

Page 8: ...g to IEEE 1588 2008 for preserving time synchronization Power supply with Power over Ethernet PoE or USB Link speeds of 100 Mbit s or 1 Gbit s determined by the connected SFP transceiver Various fiber...

Page 9: ...device with a USB charger or a PC laptop 5 SFP port Insert your SFP transceiver and connect the optical fiber cable CAUTION Minor or moderate injury may occur The optical fiber SFP transceiver module...

Page 10: ...100 Mbit s Twisted pair Ethernet cable Link speed 100 Mbit s Link speed mismatch If the twisted pair Ethernet link partner of EMCON 200 does not support the link speed of the connected SFP transceive...

Page 11: ...he two directions i e fiber to copper and copper to fiber The asymmetry of the packet delays affects the PTP path delay measurements and this influences the PTP time synchronization accuracy in the ne...

Page 12: ...Ethernet network on both ends of the line to the optical fiber cabling Again the packet asymmetry created by the first EMCON 200 media converter is compensated by the second EMCON 200 media converter...

Page 13: ...ipment PSE such as OMICRON s CMC or DANEO 400 devices If no PSE is available you can use a PoE injector instead 9 2 USB You can establish the power supply for EMCON 200 via its Micro B USB 2 0 port Us...

Page 14: ...lay mechanism Supports Layer 2 with without VLAN IPv4 and IPv6 transport mechanisms No configuration required Suitable for PTP profiles such as IEC 61850 9 3 or IEEE C37 238 2011 PTP transparent clock...

Page 15: ...itions Operating temperature 25 C 50 C 13 F 122 F Humidity 5 95 relative humidity no condensation Safety standards Europe EN 62368 1 USA UL 62368 1 International IEC 62368 1 Electromagnetic compatibil...

Page 16: ...r of your choice at your own responsibility SFP transceivers are not included in the delivery but you can order the following recommended SFP transceivers separately Type Media Wavelength Distance Ord...

Page 17: ...nally you can find the OMICRON Service Center or OMICRON Sales Partner closest to you at www omicronenergy com Customer Portal stay informed www omicronenergy com customer The Customer Portal on our w...

Page 18: ...EMCON 200 18 OMICRON...