276
Pulse Outputs
Section 5-3
PLC Setup
The various origin return parameters are set in the PLC Setup.
Origin Return Parameters
Explanation of the Origin Return Parameters
Origin Search/Return
Initial Speed
Sets the motor's starting speed when the origin return is executed. Specify
the speed in the number of pulses per second (pps).
Origin Return Target
Speed
Sets the motor's target speed when the origin return is executed. Specify the
speed in the number of pulses per second (pps).
Origin Return
Acceleration Rate
Sets the motor's acceleration rate when the origin return operation starts.
Specify the amount to increase the speed (Hz) per 4-ms interval.
Name
Settings
Remarks
Origin search/return initial
speed
X/XA CPU Units:
Unit version 1.1 and later:
• Pulse outputs 0 to 3:
00000000 to 000186A0 hex
(0 Hz to 100 kHz)
Unit version 1.0 and earlier:
• Pulse outputs 0 and 1:
00000000 to 000186A0 hex
(0 Hz to 100 kHz)
• Pulse outputs 2 and 3:
00000000 to 00007530 hex
(0 Hz to 30 kHz)
Y CPU Units:
• Pulse outputs 0 and 1:
00000000 to 000F4240 hex
(0 Hz to 1 MHz)
• Pulse outputs 2 and 3:
00000000 to 000186A0 hex
(0 Hz to 100 kHz)
Start of operation
Origin return target speed
X/XA CPU Units:
Unit version 1.1 and later:
• Pulse outputs 0 to 3:
00000001 to 000186A0 hex
(1 Hz to 100 kHz)
Unit version 1.0 and earlier:
• Pulse outputs 0 and 1:
00000001 to 000186A0 hex
(1 Hz to 100 kHz)
• Pulse outputs 2 and 3:
00000001 to 00007530 hex
(1 Hz to 30 kHz)
Y CPU Units:
• Pulse outputs 0 and 1:
00000001 to 000F4240 hex
(1 Hz to 1 MHz)
• Pulse outputs 2 and 3:
00000001 to 000186A0 hex
(1 Hz to 100 kHz)
Start of operation
Origin return acceleration rate
0001 to FFFF hex
(1 to 65,535 Hz/4 ms)
Origin return deceleration rate
0001 to FFFF hex
(1 to 65,535 Hz/4 ms)
Summary of Contents for Sysmac CP1H
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised October 2014...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 76: ...42 Function Blocks Section 1 5...
Page 176: ...142 CP series Expansion I O Unit Wiring Section 3 6...
Page 372: ...338 Analog I O XA CPU Units Section 5 5...
Page 578: ...544 Trouble Shooting Section 8 7...
Page 622: ...588 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 668: ...634 Standard Models Appendix A...
Page 744: ...710 Auxiliary Area Allocations by Address Appendix D...
Page 771: ...737 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 772: ...738 Connections to Serial Communications Option Boards Appendix F...
Page 800: ...766 Specifications for External Power Supply Expansion Appendix H...
Page 806: ...772 Index W Work Area 165 work bits 165 work words 165 write protection 379...
Page 808: ...774 Revision History...
Page 809: ......