13
Features and Main Functions
Section 1-1
Note
(1) The Modbus-RTU easy master (available for all models) makes it easy to
control Modbus Slaves (such as Inverters) with serial communications.
After the Modbus Slave address, function, and data have been preset in
a fixed memory area (DM), messages can be sent or received indepen-
dently of the program by turning software switches.
(2) By using the serial PLC Links (available for all models), a maximum of 10
words of data per CPU Unit can be shared independently of the program
among a maximum of nine CPU Units (CP1H-CP1H-CJ1M) using RS-
422A/485 Option Boards.
7-segment LED
Display (All Models)
A two-digit 7-segment LED display makes it easy to monitor PLC status.
This improves the human-machine interface for maintenance, making it easier
to detect troubles that may occur during machine operation.
• Displays error codes and details for errors detected by the CPU Unit.
Modbus-RTU
Communications can be executed independently of
the program by setting a Modbus-RTU command in
the DM and turning ON a software switch.
Inverter
SYSMAC
CP1H
BATTERY
MEMORY
PERIPHERAL
POWER
ERR/ALM
BKUP
100CH
101CH
1CH
COMM
EXP
L1
L2/N
COM
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
00
01
02
03
04
06
00
01
03
04
06
COM
COM
COM
COM
05
07
COM
02
COM
05
07
IN
OUT
SYSMAC
CP1H
BATTERY
MEMORY
PERIPHERAL
POWER
ERR/ALM
BKUP
100CH
101CH
1CH
COMM
EXP
L1
L2/N
COM
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
00
01
02
03
04
06
00
01
03
04
06
COM
COM
COM
COM
05
07
COM
02
COM
05
07
IN
OUT
SYSMAC
CP1H
BATTERY
MEMORY
PERIPHERAL
POWER
ERR/ALM
BKUP
RUN
INH
PRPHL
100CH
101CH
COMM
COMM
EXP
L1
L2/N
COM
0CH
1CH
01
03
05
07
09
11
01
03
05
07
09
11
00
02
04
06
08
10
00
02
04
06
08
10
00
01
02
03
04
06
00
01
03
04
06
COM
COM
COM
COM
05
07
COM
02
COM
05
07
IN
OUT
RS-422A/485
CP1H CPU Unit
(Master)
Data sharing
CP1H CPU Unit
(Slave)
CP1H CPU Unit
(Slave)
CJ1M CPU Unit
(Slave)
8 CPU Units max.
2-digit 7-segment LED display
Summary of Contents for Sysmac CP1H
Page 2: ......
Page 3: ...CP1H X40D CP1H XA40D CP1H Y20DT D CP1H CPU Unit Operation Manual Revised October 2014...
Page 4: ...iv...
Page 10: ...x...
Page 18: ...xviii...
Page 22: ...xxii...
Page 34: ...xxxiv Conformance to EC Directives 6...
Page 76: ...42 Function Blocks Section 1 5...
Page 176: ...142 CP series Expansion I O Unit Wiring Section 3 6...
Page 372: ...338 Analog I O XA CPU Units Section 5 5...
Page 578: ...544 Trouble Shooting Section 8 7...
Page 622: ...588 Sample Application Section 9 12 Network Settings Network Tab Network Settings Driver Tab...
Page 668: ...634 Standard Models Appendix A...
Page 744: ...710 Auxiliary Area Allocations by Address Appendix D...
Page 771: ...737 Connections to Serial Communications Option Boards Appendix F Connecting to Unit...
Page 772: ...738 Connections to Serial Communications Option Boards Appendix F...
Page 800: ...766 Specifications for External Power Supply Expansion Appendix H...
Page 806: ...772 Index W Work Area 165 work bits 165 work words 165 write protection 379...
Page 808: ...774 Revision History...
Page 809: ......