![background image](http://html1.mh-extra.com/html/omron/devicenet-safety/devicenet-safety_system-configuration-manual_743566075.webp)
41
Menu List
Section 3-2
3-2-4
Network Menu
Submenu
Description
Offline Online
Display Mode 2
Switches to the detailed display mode 2, which displays the configu-
ration based on the slave devices.
Refer to
3-2-10 Main Window Display Modes
.
O
O
Open All Devices
Displays all of the devices set for communications with the device
that the configuration is based on. This function can be used only in
Detailed Display Mode 1 or 2.
O
O
Close All Devices
Hides all of the devices set for communications with the device that
the configuration is based on. This function can be used only in
Detailed Display Mode 1 or 2.
O
O
Hardware List
Displays or hides the Hardware List.
O
O
Network Structure
Displays or hides the Network Configuration Window.
Refer to
Network Structure
in
3-2-10 Main Window Display Modes
.
O
O
Submenu
Description
Offline Online
Connect
Connects the Network Configurator to the network.
Refer to
3-3 Connecting to the Network
.
O
×
Disconnect
Disconnects the Network Configurator from the network.
Refer to
3-3 Connecting to the Network
.
×
O
Change Connect Network Port
Changes the destination network port.
Refer to
3-3-5 Changing a Connected Network
.
×
O
Move Network
Switches the network to connect.
(Not normally used for DeviceNet Safety.)
×
O
Wireless Net-
work
Move to Upper Net-
work
Displays the network one layer above the current network
in the wireless networks.
(Not normally used for DeviceNet Safety.)
×
O
Move to Lower Net-
work
Displays the network one layer below the current network
in the wireless networks.
(Not normally used for DeviceNet Safety.)
×
O
Upload
Uploads all the device parameters in the network to the
Network Configurator.
Refer to
Uploading the Network Configuration from the
Actual Network (Network Upload)
in
3-4 Creating a Virtual
Network
.
×
O
Download
Downloads all the device parameters in the Network Con-
figurator to the devices in the network.
Refer to
3-7-3 Downloading Device Parameters
.
×
O
Verify Structure
Verifies the current network configuration in the Network
Configurator with the actual network configuration of the
destination online connection.
×
O
I/O Connec-
tion
Start
Establishes an I/O connection for the specified device.
(Can be used only with EtherNet/IP.)
×
O
Stop
Stops the I/O connection for the specified device. (Can be
used only with EtherNet/IP.)
×
O
Update Maintenance Information
Updates the maintenance information of each device to the
latest information.
×
O
Update Device Status
Updates the status information for each device to the most
recently updated information.
×
O
View Device’s Connection Structure
Tree
Displays the connection configuration of the entire system.
Refer to
Device’s Connection Structure Tree Display
in
3-2-
10 Main Window Display Modes
.
O
O
Check Connection
Checks the consistency of all the connections.
O
O
Edit All Connections
Makes batch settings for all connections in the system.
Refer to
5-1-4 Listing and Setting Connection Parameters
.
O
O
Add
DeviceNet
Adds a DeviceNet network in the Network Configuration
Window.
O
O
EtherNet/IP
Adds an EtherNet/IP network in the Network Configuration
Window.
O
O
Copy
Copies the selected network configuration.
O
O
Summary of Contents for DeviceNet Safety
Page 1: ...SYSTEM CONFIGURATION MANUAL Cat No Z905 E1 07 DeviceNet Safety...
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...DeviceNet Safety System Configuration Manual Revised July 2009...
Page 6: ...iv...
Page 11: ...ix TABLE OF CONTENTS Appendix 277 Glossary 333 Index 335 Revision History 339...
Page 12: ......
Page 14: ...xii...
Page 18: ...xvi...
Page 68: ......
Page 122: ......
Page 167: ...133 Safety Slave Settings Section 5 2...
Page 234: ......
Page 266: ......
Page 366: ......
Page 372: ......
Page 374: ......
Page 375: ......