manualshive.com logo in svg
background image

RouterBOARD SXT 5HnD 

Quick Setup Guide and Warranty Information

 

 

The RouterBOARD SXT 5HnD comes as a complete set, and 
includes a built in 802.11n dual chain wireless device, and a dual 
polarization 16dBi antenna. It has one BASE-T 10/100 ethernet 
connector which supports MDI-X auto detection. 
 

First use 
 

1.

 

Connect an ethernet cable to the ethernet port behind the small 
plastic door 
 

2.

 

The SXT accepts 24V Passive PoE from a PoE injector 
 

3.

 

The default IP address from LAN is 192.168.88.1 for configuration 
 

4.

 

Username is 

admin 

and there is no password 

 

Powering 
 

The board accepts powering from the ethernet port (Passive PoE): 
 

 

Ethernet port accepts passive Power over Ethernet 8-30V DC. Package 

contains a 24V adapter. Maximum power consumption of the device is 7W.

 

 

Booting process 
 

This device doesn't come fitted with a Serial Port connector, so initial connection has to be done via the Ethernet cable, using the 

MikroTik Winbox utility. Winbox should be used to connect to the default IP address of 

192.168.88.1 

with the username 

admin 

and no 

password. 
 
In case IP connection is not available, Winbox can also be used to connect to the MAC address of the device. More information here: 
 

http://wiki.mikrotik.com/wiki/First_time_startup 

 
In case you wish to boot the device from network, for example to use MikroTik Netinstall, hold the RESET button of the device when 
starting it until the LED LD600 light turns off (behind the small door), and SXT will start to look for Netinstall servers. 
 

 
Mounting 
 

With the clip pointed forward, slide the mounting bracket into the rail on the bottom of the case, until the clip clicks into place. The 
SXT comes bundled with a hose clamp - guide the clamp through the opening in the bracket and around the pole where it will be 
mounted. Tighten the hose clamp screw when alignment is complete. Two screw holes are provided as additional security agains 
accidental bracket movement.  
 
The SXT device has a sliding door, behind which the ethernet port, and the reset jumpers are located. This door can be also 
secured shut with a screw in the provided screw hole. 
 

 
Extension Slots and Ports 
 

 

One built in wireless card and one ethernet port. 

 

 
Buttons and Jumpers 
 

 

RouterOS reset jumper hole (access through the plastic door) – resets RouterOS software to defaults. Must short circuit the 

metallic sides of the hole (with a screwdriver, for example) and boot the device. Hold screwdriver in place until RouterOS 
configuration is cleared. 
 

 

RouterBOOT reset button (access through the plastic door) has two functions: 

 

Отзывы: