224
Connection Status Tables
Section 8-1
0C:0002
The Safety Slave is in
IDLE mode
The NE1A-series Controller operating as a Safety Slave is in IDLE mode, and
safety I/O connection cannot be established. Change the operating mode to
RUN mode.
D0:0001
IDLE Mode
The NE1A-series Controller that is the Safety Master (d6/b6 is displayed) is in
IDLE mode, and has not started a safety I/O connection.
Change the NE1A-series Safety Master operating mode to RUN mode.
Status
Countermeasure