86
Device Reset and Status Change
Section 3-10
3-10-3 Reset Types and Device Status
Resetting may not be supported for some types of reset and device status.
3-10-4 Changing Device Status
Changing the device status is not supported by all devices.
The NE1A-series Controller can switch between IDLE mode and RUN mode.
For details on NE1A-series Controller modes, refer to the
Safety Network
Controller Operation Manual (Z906)
.
For DST1-series Safety I/O Terminals, there is no need to change modes.
Change the device mode using either of the following methods. This function
is enabled only when the Network Configurator is online.
With Network Configurator Ver. 2.0
@
or higher, modes can be changed all at
once by selecting multiple devices.
1. Select a device, and then select
Device - Change Mode
followed by the
desired mode.
2. Select a device, and then right-click the device and select
Change Mode
followed by the desired mode.
Next, the password input window for the device will be displayed. Enter the
password for the selected devices and click the
OK
Button.
IMPORTANT
The mode cannot be changed in the EtherNet/IP Network Window for the
NE1A-SCPU01-EIP or NE1A-SCPU02-EIP. Change the mode in the
DeviceNet Network Window.
Reset type
Device status
Safety connec-
tion being estab-
lished and
configuration
locked.
Safety connec-
tion being estab-
lished and
configuration
locked.
Safety connec-
tion not estab-
lished and
configuration
locked.
Safety connec-
tion not estab-
lished and
configuration
locked.
Emulate cycling
power
Unable to reset.
Unable to reset.
Able to reset.
Able to reset.
Return to the out-
of-box configura-
tion, and then
emulate cycling
power.
Unable to reset.
Unable to reset.
Unable to reset.
Able to reset.
Return informa-
tion except for
specified parame-
ters to the out-of-
box configuration,
and then emulate
cycling power.
Unable to reset.
Unable to reset.
Unable to reset.
Able to reset.
Summary of Contents for DeviceNet Safety
Page 1: ...SYSTEM CONFIGURATION MANUAL Cat No Z905 E1 07 DeviceNet Safety...
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...DeviceNet Safety System Configuration Manual Revised July 2009...
Page 6: ...iv...
Page 11: ...ix TABLE OF CONTENTS Appendix 277 Glossary 333 Index 335 Revision History 339...