Note
Data cannot be converted to a lower version, such as from unit version 2.0 to
unit version 1.0.
Precautions Updating from Network Configurator Version 1.3
@
to a Higher Version
Data Compatibility
Data created using Network Configurator version 1.3
@
can be used with a
higher version without any problems if converted as outlined below. Data cre-
ated with higher versions cannot be used with lower versions; the data upload
from the device will fail when loading the project file.
Procedure for Converting Data from Version 1.3
@
to a Higher Version
Version 1.5
@
and higher have improved safety check functions, so
version programs from lower versions will need to be checked for
safety. Use the following procedure to check programs.
a.
Click the
Logic
Tab on the Edit Device Parameters Window of the
NE1A-series Controller and click the
Edit
Button to start the Logic Ed-
itor.
b.
Select
Edit - Find Function Blocks with Open Connections
to
check that all function block I/O have connections.
c.
Select
File - Apply
to save the logic program then exit the editing of
the logic program.
d.
Return to the NE1A-series Controller's Edit Device Parameters Win-
dow and click the
OK
Button.
Note
Data created using version 1.3
@
cannot be monitored online.
Always convert the data to version 1.5
@
and download it before
monitoring online.
Handling Function Blocks with Open I/O Connections
Function block outputs with open connections in version 1.3
@
data could still
be downloaded (see following diagram).
Download cannot be executed with version 1.5
@
or higher, however, if there
are outputs with open connections (to improve the program validity).
For this reason, data created using version 1.3
@
cannot be downloaded as is
for use with version 1.5
@
or higher. If open connections exist in version 1.3
@
data, use the Search Open Connection function and use the Set Output Point
Tab Page in the Safety Gate Monitoring Window for the function block with
open connections to disable the outputs or connect the open connections to
output I/O tags.
Note
Versions 1.5
@
and higher have functions for creating text boxes on program
screens and changing the I/O tag color. The text box and I/O color data is not
Open connection
Summary of Contents for DeviceNet Safety
Page 1: ...SYSTEM CONFIGURATION MANUAL Cat No Z905 E1 07 DeviceNet Safety...
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...DeviceNet Safety System Configuration Manual Revised July 2009...
Page 6: ...iv...
Page 11: ...ix TABLE OF CONTENTS Appendix 277 Glossary 333 Index 335 Revision History 339...
Page 12: ......
Page 14: ...xii...
Page 18: ...xvi...
Page 68: ......
Page 122: ......
Page 167: ...133 Safety Slave Settings Section 5 2...
Page 234: ......
Page 266: ......
Page 366: ......
Page 372: ......
Page 374: ......
Page 375: ......