196
Programming
Section 6-3
6-3-8
Updating the Program
If the I/O tags of the Safety Slaves that configure the NE1A-series Controller’s
local I/O and connections are changed (e.g., by adding or deleting I/O tags),
the user must start the Logic Editor and check the program.
If the user downloads the parameters to the NE1A-series Controller without
starting the Logic Editor, a download error will occur in the Logic Editor
because of data inconsistency. If this error occurs, start the Logic Editor and
check the program, making any required modifications.
6-3-9
Monitoring the Program
The I/O tag values and signal states of connections with function blocks can
be monitored online in the Logic Editor Window. Make sure that the Network
Configurator is connected to the network and that the NE1A-series Controller
being monitored is in RUN state before starting online program monitoring.
Starting Online Monitoring
Start online monitoring using either of the following methods:
1.
Select
Function
-
Monitoring
from the menu bar.
2.
Click the
Monitoring
Button on the toolbar.
During monitoring, the I/O tags or connections that are ON will be displayed in
a darker green color.
User-defined function block contents can be monitored.
Use the following procedure to start online monitoring.
Summary of Contents for DeviceNet Safety
Page 1: ...SYSTEM CONFIGURATION MANUAL Cat No Z905 E1 07 DeviceNet Safety...
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ...DeviceNet Safety System Configuration Manual Revised July 2009...
Page 6: ...iv...
Page 11: ...ix TABLE OF CONTENTS Appendix 277 Glossary 333 Index 335 Revision History 339...
Page 12: ......
Page 14: ...xii...
Page 18: ...xvi...
Page 68: ......
Page 122: ......
Page 167: ...133 Safety Slave Settings Section 5 2...
Page 234: ......
Page 266: ......
Page 366: ......
Page 372: ......
Page 374: ......
Page 375: ......