06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
54
5204 Appl.
Starterror
Status
The device received another start signal during printing/applying a label.
Precondition: Parameter
APPLICATOR PARA > Start error stop
or
DP INTERFACE > Start error stop
is set to
On
.
Measure
Check the labelling procedure; increase the product distance.
Set parameter
Start error stop
to
Off
.
5205 Applicator
gen.
Status
General software error
Measure
Please read the notes in section
General software errors
.
5206 Applicator
resp.
Status
Communication with the AI exceeded a given time frame.
Measure
Switch the printer off and on again after half a minute. If the error still
occurs after several trys, please contact our technical support.
5207
Appl. driver 1
Status
Shortcut or overheat at power output 1 at the applicator connector (CN603)
on the AI board. The power output 1 comprises the following output signals:
•
Cylinder
•
Vacuum
•
Airstream Support
•
Blow On
Measure
Check the connections.
5208
Appl. driver 2
Status
Shortcut or overheat at power output 2 at the applicator connector (CN603)
on the AI board. The power output 2 comprises the following output signals:
•
BTS
•
Reserved 1
•
Reserved 2
•
Reserved 3
Measure
Check the connections.
5209
Appl. driver 3
Status
Shortcut or overheat at power output 3 at the machine status connector
(CN602) on the AI board. The power output 3 comprises the following
output signals:
•
Error
•
Warning
•
Ready
Measure