06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
109
OLV PARAMETERS
This menu only appears, if an online verifier (OLV) is connected to the
printer. For this, the parameter
INTERFACE PARA > COM2 PORT > Function Option
must
be set to „Barcode OLV“.
Verify mode
64-xx
ALX 92x
DPM
PEM
Only if
OLV PARAMETER > Cancel. printing
= „On“.
All bar codes
All bar codes are being checked according to the limits set at the printer.
Easy-Plug print jobs don´t have to be modified when using this setting.
Easyplug select.
Only those bar codes are being verified, which have the „V“ set in the com-
mand option.
For details refer to the Easy-Plug manual, command #YB.
Cancel. printing
64-xx
ALX 92x
DPM
PEM
64-xx: Parameter is not supported for dispenser version.
Cancellation printing
Off
No cancellation printing.
On
If no validation data for the printed bar code was sent, or if the bar code ex-
ceeds the set limits, the faulty printed label is cancelled. Afterwards, the same
label is reprinted. The amount of reprints can be set with the parameter „Re-
print quantity“. If the error still occurs after the so defined quantity of labels
was reprinted, the printing stops and an adequate error message appears.
Reprint quantity
64-xx
ALX 92x
DPM
PEM
Only, if
OLV PARAMETER > Cancel. printing
= „On“.
Defines the maximum amount of reprint attempts after a bar code read error.
xxx
Setting range: 0 to 10, Unit interval: 1; Default setting: 0
OLV mode
64-xx
ALX 92x
DPM
PEM
Fast legacy
No additional material feed is made, if the bar code is near the end of a label.
An additional material feed is only made if the last label of a job is printed and
the printer has to stop. This is the behaviour of a Gen. 1 printer with firmware
3.40.
Limitations:
•
OLV PARAMETERS > Cancel. printing
is not available