06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
98
Speed Adaption
ALX 92x
DPM
Aktivieren der Geschwindigkeits-Adaption (APSF)
On
The dispensing speed adapts automatically to match the speed of the con-
veyor belt.
Prerequisites:
•
APSF kit installed
•
Rotary encoder installed
•
The following parameters must be set to match the applied rotary encoder:
– DISPENSER PARA > Encoder Type
– DISPENSER PARA > Encoder Resol.
– DISPENSER PARA > Encoder Diameter
Off
(Default setting) The dispensing speed remains constant, at the value that
was set using parameter
PRINT PARAMETERS > Print speed
.
Encoder Type
ALX 92x
DPM
Type of rotary encoder used.
Only if
DISPENSER PARA > Speed Adaption
= „On“
Single Phase
(Default setting) Setting for single phase rotary encoder
2 Phases normal
Setting for normal 2 phase rotary encoder
2 Phases invert.
Setting for inverted 2 phase rotary encoder
Encoder Resol.
ALX 92x
DPM
Resolution of the rotary encoder used.
Only if
DISPENSER PARA > Speed Adaption
= „On“
xxxx
Setting range: 0,0 bis 9999 pulses/turn; Default setting: 500
Encoder Diameter
ALX 92x
DPM
Diameter of the measuring wheel at the rotary encoder used.
Only if
DISPENSER PARA > Speed Adaption
= „On“
xxx,x
Setting range: 0,0 bis 200,0 mm; Default setting: 64,0
200.0 mm
20.6 var