06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
110
•
It is not recommended to use the setting „Fast legacy“ as a standard, as
some unexpected behavior, depending on the label format, may occur.
Each label format has to be tested explicitly.
fast
Standard verification mode.
slow
Each print job is proceeded as if it contained counting fields. Additionally,
each labels is moved forward underneath the laser beam and backwards
again. This procedure slows down the label throughput, but on the other hand
it ensures that the correct counting field content is printed after an error oc-
cured.
Ref Decode
64-xx
ALX 92x
DPM
PEM
Only if
OLV PARAMETER > Cancel. printing
= „On“.
No Test
The bar code doesn´t have to be decodable.
Pass
The bar code must be decodable.
Decodability
64-xx
ALX 92x
DPM
PEM
Only if
OLV PARAMETER > Cancel. printing
= „On“.
Condition: Value >= Limit.
xxx
Setting range: -1 to 100; Unit interval: 1; -1 = No checking.
Modulation
64-xx
ALX 92x
DPM
PEM
Only if
OLV PARAMETER > Cancel. printing
= „On“.
Condition: Value >= Limit.
xxx
Setting range: -1 to 100; Unit interval: 1; -1 = No checking.
Defects
64-xx
ALX 92x
DPM
PEM
Only if
OLV PARAMETER > Cancel. printing
= „On“.
Condition: Value <= Limit.
xxx
Setting range: -1 to 100; Unit interval: 1; -1 = No checking.
Edge contrast
64-xx
ALX 92x
DPM
PEM
Only if
OLV PARAMETER > Cancel. printing
= „On“.
Condition: Value >= Limit.
xxx
Setting range: -1 to 100; Unit interval: 1; -1 = No checking.