06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
40
Measure
2
1. Press the Cut button to deactivate the acoustic signal.
2. Press the Feed button in order to acknowledge the status report.
Display: OFFLINE x JOBS
3. Insert a new ribbon.
4. Press the Online button: processing of the job continues, gap LS is
reinitialised.
5009
USI start error
Status
This status message can only be triggered with activated parameter
DP INTERFACE > Start error stop
. It occurs, if another start signal is given while
printing a label.
Measure
Acknowledge by pressing the Online button. Press the Feed button
afterwards to proceed with the print job.
5012
Delete H8 loader
Status
Error while loading the H8 firmware: the old firmware on the machine could
not be deleted.
Measure
Acknowledge by pressing the Online button.
Retry loading the firmware.
If the error occurs repeatedly, the bootloader must be loaded newly.
5013
Prog H8 loader
Status
Error while loading the H8 firmware: the new firmware could not be written.
Measure
Acknowledge by pressing the Online button.
Retry loading the firmware.
If the error occurs repeatedly, the bootloader must be loaded newly.
5014 Power
Measure
Acknowledge by pressing the Online button.