06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
25
1335
#YV Field cont.
Status
Content of the #YV field (variables data field) could not be pasted.
Measure
Acknowledge by pressing the Online button.
Please read the notes in section
Easy-Plug errors
.
1336
#YV no. incorr.
Status
#YV field (variables data field) with the given no. not found.
Measure
Acknowledge by pressing the Online button.
Check the number of the #YV field.
Please read the notes in section
Easy-Plug errors
.
1390
Web width zero
Status
The printer was set to printing several label rows (Easy Plug command
#ER, n > 1); but the label width was by fault set to zero (b = 0).
Measure
Correct the #ER command regarding the setting of parameter b.
Please read the notes in section
Easy-Plug errors
.
1391
Web > Width
Status
The printer was set to printing several label rows (Easy Plug command
#ER, n > 1); but both or one of the parameters n and b are set in a way that
n * b (label row width * no. of rows) exceeds the material width.
Measure
Correct the #ER command regarding the setting of parameters n and b.
Please read the notes in section
Easy-Plug errors
.
1392
Job memory full
Status
The error can have several causes.
Measure
Please read the notes in section
Unspecific errors
.
1393
Job struct creat
Status
The error can have several causes.
Measure
Please read the notes in section
Unspecific errors
.
1394 Invalidation
Status
General software error
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.