06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
76
9024
Not possible !
Status
Detecting the material length (a function, which is normally used with MLI)
is not possible, because a printjob is currently processed.
Measure
Retry as soon as the printjob is processed.
9030
Log file:CF full
Status
An attempt to store data on the memory card was not successful, because
of a full card.
Measure
Clear some storage space on the memory card, or
Insert an empty memory card.
9031
Log file: nnnn
Status
File
access
error.
nnnn
= error code of the operating system.
Measure
Repeat the operation, which led to this message. If it comes to this
message repeatedly, send a message to the Technical Support, including
the error code.
9032
EP file log stop
Status
Internal error during Easy-Plug file logging (
SPECIAL PARAMETER >
EasyPl. file log
).
Measure
Repeat operation. If the error occurs repeatedly: switch off the file logging.
Use parameter
SPECIAL PARAMETER > EasyPl. file log
only for error analysis
purposes. Using the parameter in continous operation can cause error
messages, which are hard to understand.
9034
Use min 16MB RAM
Status
The printer has not enough RAM. The applied firmware version needs at
least 16 MB RAM for faultless operation.
Measure
Extend the pritners RAM.
9035
No printpr. stop
Status
This status message may appear during the loading of new firmware onto
the H8 (64 Bit) or onto boards, which are connected to the H8 (e.g.
Applikator Interface).
Measure
Switch the printer off and on again and retry the firmware loading.
9036
DMA switch off
Status
An error status of the DMA controler was discovered, which can only be
cured by switching off the device.
A reset is not sufficient!
Measure
Switch the device off and on again.