06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
43
[10] Positive and negative offset in relation to the feed direction (arrow).
Bar code multip.
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Bar code height scaling factor
Increases the bar code height defined in the label layout (Easy-Plug) by multi-
plication by a factor of 1 to 10.
x
Setting range: 1 to 10; Unit interval: 1; Default setting: 1
The printed bar code height calculates starting with the value defined in the
label layout multiplied by the scaling factor x.
Tradit. Imaging
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
In production mode only.
Up to firmware version x.31, the barcode height was calculated with the
formula:
with x =
PRINT PARAMETERS > Barcode Multi.
By doing so, the printed barcode height in millimeters was by 1 higher than
the value defined in the layout (1 --> 2 mm, 2 --> 3 mm, etc.)
1)
.
From firmware version x.31 on, the printed barcode is exactly as high in mil-
limeters, as the value in the layout is (1 --> 1 mm, 2 --> 2 mm, etc.)
1
.
No
New height calculation (1 --> 1 mm, 2 --> 2 mm, etc.) is applied (default set-
ting).
The plain copy line is printed with OCR-B font.
Yes
Setting for customers with print layouts based on the
old
height calculation
scheme.
1) Assumed that
PRINT PARAMETERS > Barcode Multi.
= „1“.
Barcodehight
Barcodehight
Layout
1
+
(
)
x
⋅
=