06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
131
The dot check can also be startet by pressing the Cut(Apply)+Feed
buttons in Off-line mode. However, in this case is no status report printed.
Head step tune
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only in production mode.
Fine adjustment of the printhead movement during the ribbon autoeconomy
motion.
x step(s)
Setting range: -15 to +15; Unit interval: 1; Default setting: 0
EasyPlug monitor
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Parameter only appears in production mode.
The parameter activates the logging of received Easy Plug data. Data is
transmitted to COM1 or COM2.
Activating this parameter may slow down the label rate. Therefore disable
the function after error analysis.
To keep the influence of the monitoring function on the data rate as low
as possible, the baud rate should be set to 115,000!
Off
(Default setting) The monitor function is disabled.
Serial Com1
The Easy-Plug monitor data is transmitted to Com1.
Serial Com2
The Easy-Plug monitor data is transmitted to Com2.
EP Monitor Mode
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Parameter only appears in production mode.
Activating this parameter may slow down the label rate. Therefore disable
the function after error analysis.
Interpreter data
(Default setting) All received Easy-Plug data, apart from immediate com-
mands, are transmitted.
All data
All received Easy-Plug data, including immediate commands, are trans-
mitted.
Head adjust
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Parameter only for authorised, trained service personnel!