06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
114
End print mode
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only with USI board.
Concerns the output signal PRINT_END at the USI interface. Determins the
signal response after printing of a label.
Mode 0
No print end signals.
Mode 1
Low, if the print module is printing a label, otherwise high.
Mode 2
High, if the print module is printing a label, otherwise low.
Mode 3
(Default setting) Low for 20 ms after printing and dispensing a label. The sig-
nal is also low, if the label material is
only
fed - triggered by pressing the feed
button or by a feed signal.
Mode 4
High for 20 ms after printing and dispensing a label. The signal is also high,
if the label material is
only
fed - triggered by pressing the feed button or by a
feed signal.
Mode 5
The PRINT_END signal is
low
as long as the material is fed forwards (even
for gap initialization).
Mode 6
The PRINT_END signal is
high
as long as the material is fed forwards (even
for gap initialization).
Reprint signal
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only with USI board.
Determins the reaction on an incoming signal at pin REPRINT\ at the USI.
Off
(Default setting) Incoming signal is ignored.
On
On a high-low toggle of the signal: The last printout is repeated.
Ribbon signal
64-xx
ALX 92x
DPM
PEM
ALX 73x (PMA)
Only with USI board.
Concerns the output signal WARNING at the USI, which signalizes the close
shortness of ribbon or material.
On
(Default setting) High, if the ribbon stack is less than the threshold value.
The threshold setting is done with the parameter
SYSTEM PARAMETER >
Foil end warning
.
Off
Ribbon signal deactivated.