TouchDownTimeout
ALX 92x
DPM
Timeout at the touchdown sensor.
Only with an AI installed.
Only visible with certain applicator types.
This time specifies the maximal wait time for the touchdown trigger event.
If the specified time is exceeded without the touchdown event, the appli-
cator continues operation in the same manner as the touchdown event
would have taken place.
No
error message will appear in this case.
xxxxx
Setting range: 100 to 99999 ms
Off