06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
57
5523
Tag address err
Status
Faulty address: The address data targets beyond the logical or physical
address range of the transponder.
Measure
Change the address.
5524 CMD
not
applicable
Status
A command cannot be interpreted by the transponder.
Measure
Change or remove the command.
5525
Tag read err
Status
The plausibility test of the read data failed. Possible reasons are:
•
The tag is out of reach of the antenna, after it has already been recognized.
•
Noise signals avoid the transmission.
Measure
Check the system for the mentioned error causes and correct them.
5526
Tag select first
Status
A read or write command was given without selecting the transponder at
first.
Measure
Add a select command before using the read/write command.
5527
Tag RF comm err
Status
Transponder and reader are unable to communicate. Possible reasons are:
•
More than one transponder is within reach of the antenna.
•
No transponder is within reach of the antenna.
Measure
Check the label material feeding; eventually remove paper jam.
5528 EEPROM
failure
Status
•
The reader cannot write on the transponder EEPROM.
•
A faulty checksum was detected before writing on the EEPROM.
Measure
Repeat the writing attempt.
Try another transponder
5529 Parameter
range
Status
Faulty address. Transponders of the same type may have memory ranges
of different sizes; according to this, the admissible addresses differ too.
The fault occurs, if a block address targets beyond the address range of the
transponder.
Measure
Change the address.
Use a transponder with a wider address range.
5530 Unknown
CMD
Status
The reader doesn´t support the used command.