06/15 Rev. 6.00-02
USER- / SERVICE MANUAL
Info-Printouts & Parameters
64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)
94
Dispenseposition
64-xx
ALX 92x
DPM
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Adjusts the dispense position in or against the feed direction. Depending on
the set dispense position, the dispensed label sticks to the backing paper with
a more or less wide strip [18]. The required width of this strip depends on the
further processing.
[18] Dispense position of the dispensed label.
x.x mm
Setting range: -30.0 to +20.0 mm; Unit interval: 0.1 mm; Default
setting: -6.0 mm
Display mode
64-xx
ALX 92x
DPM
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
Makes the
already
printed labels appear in the display instead of the
not yet
printed ones.
Job rest quant.
Display of the
not yet
printed labels of a print job.
The counter keeps it´s value even after switching the printer off.
Dispense counter
Counting of start pulses. Activate the counter by selecting "Dispense coun-
ter". The counted number appears on the display after the parameter
Dispense counter
(see below) has been selected.
Dispense counter
64-xx
ALX 92x
DPM
Only if
SYSTEM PARAMETER > Periph. device
= „Dispenser“.
The displayed value can be varied by pressing the Cut or Feed button.
There are two ways of setting back the counter:
•
Set the parameter
Display mode
(see above) to "Job rest quant." , then back to
"Dispense counter" and confirm by pressing the Online button.
•
Reduce the displayed number by pressing the Cut button.
Dispensed label
Dispense position
Dispensing edge
Backing paper
Z0040E
.cdr
Dispense counter
xxxxxx
xxxxxx = Number of dispensed labels.