4105
No OLV response
Status
This error may occur shortly after switching on the printer with the OLV
device already switched on. It indicates, that the OLV version number was
not successfully read.
Possible causes are:
•
Wrong connection cable between OLV and printer
•
Faulty interface parameter setting for Com2
•
Power supply of the OLV interrupted or not available
•
Defective I/O board (Com2)
Measure
Check the possible causes of failure and exchange defective parts.
4106 OLV
Software
Status
General software error
Measure
Please read the notes in section
General software errors
.
5000 Bus
device
Status
One of the devices connected to the I
2
C bus (e.g. output stage boards)
does not respond. This message appears mostly first in a sequence of two
or three status messages, which help to isolate the error source.
Measure
Acknowledge by pressing the Online button.
Switch printer off and back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
Example
The
parameter
SYSTEM PARAMETERS > Periph. device
is set to "Cutter" without
an output stage board for a cutter being installed. The following status
messages appear one after another:
1. Status 5000
Bus device
Generally tells, that something went wrong
with I
2
C bus communication.
Press Online button.
2. Status 5005
Knife-fault
Either no output stage board is prepared to
drive a cutter, or the I
2
C bus data cable is not
connected to the output stage board (this
message appears only in one of those two
cases, alternative status messages see Tab.
2)
Press Online button.
3. Status 5020
I2C Timeout 4
Time limit exceeded without getting an answer
from device no. 4 (4 = Cutter, see Tab. 4)
(alternative status messages see Tab. 3)
Press Online button
One of the following status messages may follow second:
Status # Text
Missing output stage for the following