06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
72
8900 Codablock
columns
Status
Bar code Codablock: illegal number of columns.
Measure
Correct number of columns.
8901 Codablock
rows
Status
Bar code Codablock: illegal number of rows.
Measure
Correct number of rows.
8902 Codablock
softw.
Status
Bar code Codablock: software error.
Measure
8903 Codablock
infogr
Status
Bar code Codablock: info not in line.
Measure
8950 Logo
open
Status
Failure when attempting to read a logo, which has previously been copied
on RAM disk or on memory card (thus using Easy Plug command #DK).
Measure
Repeat loading the logo via #DK command.
In cases of continuous occurence of this error, please contact the technical
support.
8951 File
format
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
8952 Not
installed
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
9000 Wrong
errornum
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.
9001 Software
Error
Status
General software error.
Measure
Switch printer off and then back on again after thirty seconds.
Please read the notes in section
General software errors
.