06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
28
1504
Param > Max
Error level
1
Status
Parameter exceeds the maximum value defined
Measure
Shorten the parameter.
1505
Param < Min
Error level
1
Status
Parameter is shorter than the admissible minimum value allowed.
Measure
Modify the parameter.
1506 No
Previous
Error level
1
Status
Graphics command is to set current row data to previous row data, but
previous row data doesn't exist.
Measure
1507
Not enough data
Error level
1
Status
Data for graphics command is not enough.
Measure
Check and modify graphics data.
1508
String Too Long
Error level
1
Status
String characters exceeds the maximum number of characters which the
particular string parameter can take.
Measure
Check and modify the command.
1509
Wrong Byte Cnts
Error level
1
Status
The row size or total size parameters is not valid (equals 0). Occurs when
download graphic or download font commands in process.
Measure
Check and modify the command.
1510 Wrong
Param
Error level
1
Status
Control characters are not allowed for discrete parameter (single letter
parameter).
Measure
Check and modify the command.
1511
Bar Parm Error
Error level
1