06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
26
1395
Label too wide
Status
A printjob contains an #IM-command which sets the label width to a
measure exceeding the maximum print width. The maximum print width
depends on the printer type.
Refer to the user manual, topic section „Specifications“ for the maximum
label width.
Measure
Reduce the label width set by the #IM-command in the concerned print job,
until the label width matches the maximum print width.
Please read the notes in section
Easy-Plug errors
.
1396
Label too long
Status
Label length setting exceeds the maximum label length. The maximum
label length depends on the memory configuration of the printer.
The info-printout „Memory Status“ shows among other data the maximum
label length. Read more about info-printouts in topic section „Info-Printouts
and Parameters“.
Measure
Reduce the label width setting.
Please read the notes in section
Easy-Plug errors
.
1397
Label too short
Status
The label length defined in the #IM command is smaller than the minimum
admissible length. The label length is set to the minimum value.
Measure
Correct the length value in the label layout definition.
Please read the notes in section
Easy-Plug errors
.
1398
Label too small
Status
The label width defined in the #IM command is smaller than the minimum
admissible width. The label width is set to the minimum value.
Measure
Correct the width value in the label layout definition.
Please read the notes in section
Easy-Plug errors
.
1404
UTF8 data wrong
Status
Character code > 0xffff
Measure
Check/change the character code.
1470 X-Offset
Status
The x-position of a layout element (graphics, text, ...) is beyond the label
margin. The element is shifted automatically to the first admissible position
at the correct side of the margin.
Measure
Check the x-positions of the layout elements and change them, if
necessary.
Please read the notes in section
Easy-Plug errors
.