06/15 Rev. 10
USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
55
5210
Appl. driver 4
Status
Shortcut or overheat at power output 4 at the machine status connector
(CN602) on the AI board. The power output 4 comprises the following
output signals:
•
Cycle
•
OD-Foil
•
OD-Sensor
•
Offline
Measure
Check the connections.
5212
Vx.x for AI rec
Status
The required AI firmware (version x.x) is not installed.
Measure
If the installed AI firmware is older than the required version:
Acknowledge message. Load AI firmware version x.x.
If the installed AI firmware is newer than the required version:
The message is acknowledged automaticallly.
5300
BLDC EEPROM err.
Status
General EEPROM read/write error on the BLDC driver board (AP 5.4 with
internal rewinder).
Measure
Switch printer off and than on again after 30 seconds. If the status message
continues to appear, change the BLDC board.
5301
BLDC rewinder Ø
Status
The stored rewinder diameter exceeds the admissible range (AP 5.4 with
internal rewinder).
Measure
Acknowledge the status message by pressing the online button.
Switch to offline mode and feed the label web for approx. 200 mm. This re-
initializes the rewinder diameter.
If the printer is switched off and on again
whithout prior initialization
, the
status message will be displayed again.
5500 Unknown
Status
General software error
Measure
Please read the notes in section
General software errors
.
5501 General
Status
General software error
Measure
Please read the notes in section
General software errors
.
5502-5551
Messages, which can only occur with RFID option
5502 RFID
internal
Status
General software error