5018
Dot check area
Status
A value is measured at the AD transformer, which should not occur with a
proper working printer. That means, the current measurement circuit inside
the power supply delivers a value which is too high. This can be a
sporadically occuring fault of the power supply (noise voltages) or a durable
defect. Another possibility is, that a dot of the printhead has a much too low
resistance – a rather unlikely option, because this dot would be quickly
overheated while printing, what would damage it and lead to a high
resistance.
Measure
Acknowledge by pressing the Online button.
Try again. If the error message continues to appear, please contact the
manufacturer.
5020
I2C Timeout xx
Status
Timeout error during communication via the I
2
C bus with the device xx (see
Tab. 4 on page 37).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5021
I2C Conf. xx
Status
Confirmation error during communication via the I
2
C bus with the device xx
(see Tab. 4 on page 37).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5022
I2C Busy xx
Status
Error during communication via the I
2
C bus with the device xx (see Tab. 4
on page 37). Device always reports that it is busy.
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5023 I2C
LAB
xx
Status
Error during communication via the I
2
C bus with the device xx (see Tab. 4
on page 37).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5024 I2C
BER
xx
Status
Error during communication via the I
2
C bus with the device xx (see Tab. 4
on page 37).
Measure
Switch printer off and then back on again after 30 sec. If the error message
continues to appear, please contact the manufacturer.
5025
I2C Polling xx
Status
Polling error during communication via the I
2
C bus with the device xx (see
Tab. 4 on page 37).