USER + SERVICE MANUAL
/Status Reports
64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6
50
5130 PSU
xxxxxxxx
Status
Failure of the power supply. "xxxxxxxx" = four byte long error code in
hexadecimal form. Every bit stands for a certain status of the power supply.
The bit is set to "1", if the status occured.
•
Byte 1: xxxxxx
xx
x
x
7 6 5 4 3 2 1 0
Output 1
(5 V logic):
The output voltage exceeds the
admissible range.
Output 2
(20-28 V printhead):
The output voltage exceeds the
admissible range.
Output 3
(galv. 24 V):
The output voltage exceeds the
admissible range.
Output 4
(48 V motor):
The output voltage exceeds the
admissible range.
Dot Check defective:
Indicates a detected power supply
fault in the course of a Dot-Check-
Measurement. Example: While
measuring the internal reference
resistance, have the admissible
tolerances been exceeded.
Fan defective:
Indicates a fan-fault, if its control
allows any error detection.
Critical overheat:
A critical temperature is set in
register "critical temperature limit". If
the critical value is exceeded, the
power supply switches off
immediately and sets this bit to 1.
Overheat:
A critical temperature is set in
register "critical temperature limit". If
the critical value is exceeded, the
power supply switches off well
controlled and sets this bit to 1.