4 STARTUP
4.2 Startup
Set the IP address by using the SLMP command with the rotary switches (SW2/SW3) on the display of the servo amplifier,
MR Configurator2, or a master station (controller). For IP address parameters, refer to chapter 7, and for details of the rotary
switches, refer to the following.
Change the IP address with the rotary switches (SW2/SW3) before powering on the servo amplifier. The IP address can be
changed by specifying a MAC address when the SLMP command (IPAddressSet) is used. For details of the commands, refer
to the following.
The IP address you set can be checked in the system configuration window of MR Configurator2.
The IP address can be set as follows.
Parameter setting
The following encoder cables are of four-wire type. When using any of these encoder cables, set [Pr. PC04] to
"1 _ _ _" to select the four-wire type. Incorrect setting will result in [AL. 16 Encoder initial communication error
1].
• MR-EKCBL30M-L
• MR-EKCBL30M-H
• MR-EKCBL40M-H
• MR-EKCBL50M-H
Set the parameters according to the structure and specifications of the machine. For details, refer to chapter 7 of this
document and chapter 5 of "MR-J4-_GF_(-RJ) Servo Amplifier Instruction Manual (Motion Mode)".
After setting the parameters, turn off the power as necessary. Then switch power on again to enable the parameter values.
Connection with controller
Set up the controller by following the manual of the controller used.
Servo-on
Enable the servo-on with the following procedure.
1.
Switch on main circuit power supply and control circuit power supply.
2.
Transmit the servo-on command from the master station (controller).
When the servo-on status is enabled, the servo amplifier is ready to operate and the servo motor is locked.
Rotary switches (SW2/SW3)
IP address
00h
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 1st octet is "192".
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
When the parameter is set to "_ _0 0", the 2nd octet is "168".
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 3rd octet is "3".
4th octet
The setting value of [Pr. PN12 (_ _ x x)] is used.
01h to FFh
1st octet
The setting value of [Pr. PN11 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 1st octet is "192".
2nd octet
The setting value of [Pr. PN11 (_ _ x x)] is used.
When the parameter is set to "_ _0 0", the 2nd octet is "168".
3rd octet
The setting value of [Pr. PN12 (x x _ _)] is used.
When the parameter is set to "0 0 _ _", the 3rd octet is "3".
4th octet
The setting value of the rotary switches (SW2/SW3) is used.