10 OBJECT DICTIONARY
10.1 Object dictionary list
255
10
2A00
to
2A0F
0
Alarm history newest
The number of entries in the
latest alarm of the alarm history
is returned.
U8
ro
Impossible
3
03h (fixed)
1
Alarm No.
The number of the alarm that has
occurred is returned. The
description is as follows.
Bit 0 to Bit 15: Alarm detail
number
Bit 16 to Bit 31: Alarm number
When no history exists, 0 is
returned.
U32
ro
Impossible
0
00000000h to
FFFFFFFFh
2
Alarm time (Hour)
Alarm occurrence time is
returned.
When no history exists, "0" is
returned.
U32
ro
Impossible
0
00000000h to
FFFFFFFFh
hour
3
Alarm2 No.
The number of the alarm that has
occurred is returned.
The description is as follows.
Bit 0 to Bit 7: Alarm detail number
Bit 8 to Bit 15: Alarm number
When no history exists, "0" is
returned.
U16
ro
Impossible
0
0000h to
FFFFh
2A40
0
Clear alarm history
Writing "1EA5h" clears the alarm
history.
U16
wo
Impossible
2A41
0
Current alarm
The alarm number of the
currently occurring alarm is
returned. When no alarm has
occurred, "00000000h" is
returned.
Bit 0 to Bit 15: Alarm detail
number
Bit 16 to Bit 31: Alarm number
U32
ro
Possible
00000000h to
FFFFFFFFh
2A42
0
Current alarm 2
The alarm number of the
currently occurring alarm is
returned. When no alarm has
occurred, "0000h" is returned.
Bit 0 to Bit 7: Alarm detail number
Bit 8 to Bit 15: Alarm number
U16
ro
Possible
0000h to
FFFFh
2A43
0
Point table error
Point table error
U8
ro
Impossible
2
02h (fixed)
1
Point table error No.
The point table No. in which a
point table error has occurred is
returned.
U16
ro
Impossible
0
00000000h to
000000FFh
2
Point table error factor
The error factor of the
corresponding point table in
which a point table error has
occurred is returned.
Bit 0: Target position error
Bit 1: reserved
Bit 2: Speed error
Bit 3: Acceleration time constant
error
Bit 4: Deceleration time constant
error
Bit 5: Dwell error
Bit 6: Auxiliary function error
Bits 7 to 31: reserved
U32
ro
Impossible
0
00000000h to
000000FDh
Index
Sub
Index
Name and function
Data
Type
Access Variable
mapping
Default
Range
Units
EEP-
ROM