7 PARAMETERS
7.2 Detailed list of parameters
PT26
*TOP2
Function
selection T-2
_ _ _ x
Electric gear fraction clear selection
0: Disabled
1: Enabled
Selecting "Enabled" clears a fraction of the previous command by the electronic gear at start of
automatic operation.
When this digit is set to "2" or higher, the setting becomes "Disabled".
This digit is available with servo amplifier with software version A7 or later.
0h
_ _ x _
Current position/command position display selection
Select the display method of the current position and command position.
0: Positioning display
1: Roll feed display
This digit is disabled when [degree] is set for "Unit for position data" in [Pr. PT01].
This digit is available with servo amplifier with software version A7 or later.
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
PT27
*ODM
Indexer method -
Operation mode
selection
_ _ _ x
For manufacturer setting
0h
_ _ x _
Manual operation method selection
0: Station JOG operation
1: JOG operation
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
PT28
*STN
Number of
stations per
rotation
Set the number of stations per rotation (number of indexer stations).
Setting "0" or "1" will be "2".
Setting range: 0 to 255
8
[stations]
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP
PS
Setting
value
Display
method
Operation mode
Status display content
Current position
Command position
_ _ 0 _
Positioning
display
Automatic/manual
Displays the actual
current position with
the machine home
position being set as
0.
Displays the command
current position with
the machine home
position being set as 0.
_ _ 1 _
Roll feed
display
Automatic Automatic
continuous
positioning
operation
Unavailable
Unavailable
Automatic
individual
positioning
operation
Displays the actual
current position with
the automatic
operation start
position being set as
0.
Starts counting from
0 when the start signal
is turned on and
displays the command
current position to the
target position.
Displays the command
position (the target
position of the point
table) during a stop.
Manual
Displays the actual
current position with
the machine home
position being set as
0.
Always displays 0.