260
10 OBJECT DICTIONARY
10.1 Object dictionary list
2BA8
0
Alarm Monitor 40 Number of
tough drive operations
The number of tough drive
operations at alarm occurrence is
returned.
I32
ro
Possible
0000h to
FFFFh
times
2BAA
0
Alarm Monitor 42 Internal
temperature of amplifier
The internal temperature of
amplifier at alarm occurrence is
returned.
I32
ro
Possible
8000h to
7FFFh
°C
2BAD
0
Alarm Monitor 45 Unit power
consumption
The unit power consumption at
alarm occurrence is returned.
I32
ro
Possible
8000h to
7FFFh
W
2BAE
0
Alarm Monitor 46 Unit total power
consumption
The unit total power consumption
at alarm occurrence is returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
Wh
2BAF
0
Alarm Monitor 47 Current
position
The current position at alarm
occurrence is returned. In the
indexer method, the value is fixed
to 0.
I32
ro
Possible
80000000h to
7FFFFFFFh
2BB0
0
Alarm Monitor 48 Command
position
The command position at alarm
occurrence is returned. In the
indexer method, the value is fixed
to 0.
I32
ro
Possible
80000000h to
7FFFFFFFh
2BB1
0
Alarm Monitor 49 Command
remaining distance
The command remaining
distance at alarm occurrence is
returned.
I32
ro
Possible
80000000h to
7FFFFFFFh
2BB2
0
Alarm Monitor 50 Point table No./
Station position No.
Point table No. or station position
No. at alarm occurrence is
returned.
I32
ro
Possible
0000h to
00FFh
2C18
0
Power ON cumulative time
The cumulative time after power
on of the servo amplifier is
returned.
U32
ro
Impossible
0
00000000h to
FFFFFFFFh
hour
2C19
0
Number of inrush relay on/off
times
The number of on/off times of the
inrush relay of the servo amplifier
is returned.
U32
ro
Impossible
0
00000000h to
FFFFFFFFh
times
Index
Sub
Index
Name and function
Data
Type
Access Variable
mapping
Default
Range
Units
EEP-
ROM
Parameter