264
10 OBJECT DICTIONARY
10.1 Object dictionary list
2C2E
0
Vibration based fault prediction
prepare status
The threshold creation progress
used for vibration failure
prediction is displayed in %. The
creation of a threshold for
vibration failure prediction will be
completed at 100%.
I16
ro
Impossible
8000h to
7FFFh
%
2C2F
0
Motor total distance
The motor total travel distance is
displayed in units of rev or m.
I32
ro
Impossible
80000000h to
7FFFFFFFh
rev
m
2D01
to
2D0A
0
Control DI 1 to Control DI 10
The on/off status of input device
can be read. The on/off status of
input device can also be set.
U16
rw
Possible
0
0000h to
FFFFh
2D11
to
2D1A
0
Status DO 1 to Status DO 10
The on/off status of output device
can be read.
U16
ro
Possible
0000h to
FFFFh
2D20
0
Velocity limit value
The speed limit value is set.
U32
rw
Possible
50000
00000000h to
instantaneous
permissible
speed
0.01 r/
min
0.01
mm/s
PT67
2D28
0
Motor rated speed
The servo motor rated speed is
returned.
U32
ro
Impossible
00000000h to
FFFFFFFFh
r/min
mm/s
2D30
0
Manufacturer Device Name 2
The number of characters (32) of
the model name of the servo
amplifier is returned.
VISIBLE
STRING
ro
Impossible
1 to 32
Manufacturer Device Name 2
The model name of the servo
amplifier is returned.
2D32
0
Manufacturer Software Version 2
The number of characters (3) of
the software version of the servo
amplifier is returned.
VISIBLE
STRING
ro
Impossible
1 to 3
Manufacturer Software Version 2
The software version of the servo
amplifier is returned.
2D33
0
Serial Number 2
The number of digits (16) of the
serial number of the servo
amplifier is returned.
VISIBLE
STRING
ro
Impossible
1 to 16
Serial Number 2
The serial number of the servo
amplifier is returned.
Index
Sub
Index
Name and function
Data
Type
Access Variable
mapping
Default
Range
Units
EEP-
ROM
Parameter